Fuel level sensor DUT-E 2Bio is designed for precision fuel level measurement in all kinds of vehicle tanks, also in tanks of fixed installations.
DUT-E 2Bio can be used as a part of a fuel monitoring system or to substitute the standard fuel meter of a vehicle.
Different fuel types (summer diesel, winter diesel and especially biodiesel) have different permittivity values. For accurate fuel volume measurement in case of switching between different types of fuel re-calibration of fuel tank is needed.
DUT-E 2Bio fuel level sensor is designed for accurate volume measurement of all types of fuel.
Re-calibration and re-configurations is not needed. DUT-E as a part of telematics system is used:
- to obtain reliable information about current fuel volume in vehicle tank;
- to define the vehicle fueling volume;
- to detect fuel theft from the tank;
- to carry out the remote tank monitoring;
- to determine fuel consumption.
Features
- configuratable thermal correction for automatic compensation based on ambient temperature;
- digital self-diagnostics to control data reliability;
- conformity to compulsory automobile standards of the European Union, Russia, and Belarus;
- no recalibration required for up to 30% length reduction of the sensor (DUT-E А5, DUT-E А10, DUT-E I);
- length increase with additional sections of DUT-E – up to 6000 mm;
- ergonomic bayonet-type fastening to save mounting time;
- sealing openings to prevent tampering;
- all the necessary mounting items and cords in delivery set;
- filter for secure protection from water and mud;
- convenient ready output signal showing fuel level in the tank in mm, fuel volume in littres, percentage of full tank capacity;
- сonfiguration via Bluetooth by connecting S6 BT Service Adapter.
Ordinary capacitive fuel level sensors.
Fuel level sensor sends overestimated fuel volume when switching from regular diesel fuel to biofuel.
DUT-E 2Bio fuel level sensor
Fuel level sensor sends real fuel volume when switching from regular diesel fuel to biofuel.
Models:
DUT 2Bio CAN: CAN (J1939) interface.
other types of output signal are produced on demand
Technical specifications:
Operation principle ....................................................... Capacitive
Measurement inaccuracy.........................................................1%
Supply voltage, V ............................... 10 .. 50, protection up to 100
Operation temperature, °С ............................................. –40 .. +85
Current consumption (DC 24/12V), mA ............................. ≤ 25/50
Probe length, mm ......................................................... 700, 1000